產(chǎn)品與市場
S2131
特點
● 良好的機(jī)械加工性,鉆孔加工鉆頭使用壽命可延長
● UV Blocking/AOI兼容
● 優(yōu)異的電性能
● PTH通孔可靠性與FR-4.0相當(dāng)
應(yīng)用領(lǐng)域
● 儀器儀表、信息家電、汽車電子、自動柜員機(jī)、游戲機(jī)等
● 對于具有CAF要求的應(yīng)用,建議客戶對其可靠性進(jìn)行系統(tǒng)評估
- 產(chǎn)品性能
- 產(chǎn)品證書
- 資料下載
Items | Method | Condition | Unit | Typical Value | |
---|---|---|---|---|---|
Tg | IPC-TM-650 2.4.25 | DSC | ℃ | 130 | |
CTE (Z-axis) | IPC-TM-650 2.4.24 | Before Tg | ppm/℃ | 60 | |
After Tg | ppm/℃ | 340 | |||
50-260℃ | % | 5.2 | |||
Thermal Stress | IPC-TM-650 2.4.13.1 | 288℃, solder dip | s | >30 | |
Volume Resistivity | IPC-TM-650 2.5.17.1 | After moisture resistance | MΩ.cm | 5.4x 108 | |
E-24/125 | MΩ.cm | 3.2 x 106 | |||
Surface Resistivity | IPC-TM-650 2.5.17.1 | After moisture resistance | MΩ | 7.6 x 107 | |
E-24/125 | MΩ | 8.5 x 106 | |||
Arc Resistance | IPC-TM-650 2.5.1 | D-48/50+D-4/23 | s | 115 | |
Dielectric Breakdown | IPC-TM-650 2.5.6 | D-48/50+D-4/23 | kV | >45 | |
Dissipation Constant (Dk) | IPC-TM-650 2.5.5.9 | 1MHz | -- | 4.5 | |
IEC 61189-2-721 | 10GHz | -- | — | ||
Dissipation Factor (Df) | IPC-TM-650 2.5.5.9 | 1MHz | -- | 0.016 | |
IEC 61189-2-721 | 10GHz | -- | — | ||
Peel Strength(1oz HTE copper foil) | IPC-TM-650 2.4.8 | A | N/mm | — | |
After thermal Stress 288℃,10s | N/mm | 1.9 | |||
125℃ | N/mm | 1.7 | |||
Flexural Strength | LW | IPC-TM-650 2.4.4 | A | MPa | 400 |
CW | IPC-TM-650 2.4.4 | A | MPa | 320 | |
Water Absorption | IPC-TM-650 2.6.2.1 | E-1/105+D-24/23 | % | 0.11 | |
CTI | IEC60112 | A | Rating | PLC 3 | |
Flammability | UL94 | C-48/23/50 | Rating | V-0 | |
E-24/125 | Rating | V-0 |
Remarks:
1. Specification sheet: IPC-4101/12, is for your reference only.
2. All the typical value is based on the 1.6mm specimen.
3. All the typical values listed above are for your reference only and not intended for specification. Please contact Shengyi Technology Co., Ltd. for detailed information. All rights from this data sheet are reserved by Shengyi Technology Co., Ltd.
Explanation:C=Humidity conditioning, D=Immersion conditioning in distilled water,E=Temperature conditioning
The first digit following the letter indicates the duration of preconditioning in hours, the second digit the preconditioning temperature in ℃ and the third digit the relative humidity.