產(chǎn)品與市場
S1141
特點(diǎn)
● T140℃(DSC)
● UV Blocking/AOI兼容
● 優(yōu)良的機(jī)械加工性能
應(yīng)用領(lǐng)域
電腦、儀器儀表、攝像機(jī)、通訊設(shè)備、電子游戲機(jī)、汽車、航空等。不適用與有CAF要求的應(yīng)用。不適用于2OZ以上厚銅、HDI及12層以上的高多層板。- 產(chǎn)品性能
- 產(chǎn)品證書
- 資料下載
Items | Method | Condition | Unit | Typical Value | |
---|---|---|---|---|---|
Tg | IPC-TM-650 2.4.25 | DSC | ℃ | 140 | |
Td | IPC-TM-650 2.4.24.6 | 5% wt. loss | ℃ | 310 | |
CTE (Z-axis) | IPC-TM-650 2.4.24 | Before Tg | ppm/℃ | 65 | |
After Tg | ppm/℃ | 300 | |||
50-260℃ | % | 4.5 | |||
CTE (X/Y-axis) | IPC-TM-650 2.4.24.5 | Before Tg | ppm/℃ | — | |
T260 | IPC-TM-650 2.4.24.1 | TMA | min | 15 | |
T288 | IPC-TM-650 2.4.24.1 | TMA | min | 2 | |
Thermal Stress | IPC-TM-650 2.4.24.13 | 288℃, solder dip | -- | 60S No Delamination | |
Volume Resistivity | IPC-TM-650 2.5.17.1 | After moisture resistance | MΩ-cm | 5.2×108 | |
E-24/125 | MΩ-cm | 5.2×106 | |||
Surface Resistivity | IPC-TM-650 2.5.17.1 | After moisture resistance | MΩ | 5.4×107 | |
E-24/125 | MΩ | 5.6×106 | |||
Arc Resistance | IPC-TM-650 2.5.1 | D-48/50+D-4/23 | s | 120 | |
Dielectric Breakdown | IPC-TM-650 2.5.6 | D-48/50+D-4/23 | kV | 60 | |
Electrical Strength | IPC-TM-650 2.5.6.2 | D-48/50+D-4/23 | kV/mm | — | |
Dissipation Constant (Dk) | IPC-TM-650 2.5.5.9 | 1MHz | -- | 4.6 | |
Dissipation Factor (Df) | IPC-TM-650 2.5.5.9 | 1MHz | -- | 0.015 | |
Peel Strength (1Oz HTE copper foil) | IPC-TM-650 2.4.8 | A | N/mm | — | |
After thermal Stress 288℃,10s | N/mm | 1.8 | |||
125℃ | N/mm | 1.6 | |||
Flexural Strength | LW | IPC-TM-650 2.4.4 | A | MPa | 600 |
CW | IPC-TM-650 2.4.4 | A | MPa | 500 | |
Water Absorption | IPC-TM-650 2.6.2.1 | E-1/105+D24/23 | % | 0.15 | |
Thermal Conductivity | ASTM E1461 | Z-axis | W/m·K | — | |
CTI | IEC60112 | A | Rating | PLC 3 | |
Flammability | UL94 | C-48/23/50 | Rating | V-0 | |
E-24/125 | Rating | V-0 |
Remarks:
1. Specification sheet: IPC-4101/21, is for your reference only.
2. All the typical value is based on the 1.6mm specimen,while the Tg is for specimen≥0.50mm.
3. All the typical value listed above is for your reference only,please turn to Shengyi Technology Co., Ltd. for detailed information, and all rights from this data sheet are reserved by Shengyi Technology Co., Ltd.
Explanations: C=Humidity conditioning, D=Immersion conditioning in distilled water, E=Temperature conditioning
The figures following the letter symbols indicate with the first digit the duration of the preconditioning in hours, with the second digit the preconditioning temperature in ℃ and with the third digit the relative humidity.